Ambient Air Monitors

Designed for gas and particle pollutant measurements to better understand atmospheric chemistry and environmental public health, these internet enabled instruments provide a near-instantaneous look at changing pollutant concentrations, with peripheral sensors for measurement of environmental and meteorological parameters.

EM-1000 Ambient Air Monitor

Model EM-10000
The  EM-10000 is designed for outdoor particulate and gas monitoring. These robust monitors provide reliable, accurate measurement of airborne contamination allowing for the detection of environmental and public health concerns. The first real time monitor to provide 6 accurate particulate size channels.

Realtime Data
6 particle size channels recorded by the EM-10000 Monitor are stored in an internal non-volatile memory at user-defined data sampling rates (1 second to -99 hours). The high time-resolution of the Model EM-10000 measurements provides a near-instantaneous look at changing airborne particulate concentrations, leading to a well-defined model of local point source influences that may disproportionately affect air quality.

Internet-Enabled
EM-1000 systems are configured to allow users to push real-time data to the cloud where sensor outputs can be visualized by authorized stakeholders.

Fully Integrated Low-Cost Air Quality Sensor System
Integration of additional sensors for measurement of environmental and meteorological parameters (relative humidity, temperature, barometric pressure, (optional) carbon dioxide – CO2, and total volatile organic compounds – TVOC) offers a more complete view of air quality.

Ambient Air Monitor
Airborne Pollution and Environmental Research
Perimeter or Fence-line Monitoring for Construction, Remediation or Hazardous Waste Sites
Mine and Quarry Fence-line Monitoring for dust control operations
City Wide or Community Air Pollution Monitoring
Roadside Emissions Monitoring
Medical Facilities Property Monitoring
Power Line Wild-Fire Monitoring
Environmental Disasters
Monitor for 24 hours a day, 7 days a week, 365 days a year
Concurrent measurement of multiple, user selectable PM sizes from 0.3um to 10 µm including TPM of particles up to 25 µm
Closed-loop humidity control for incoming airstream (to provide more accurate particulate sizing)
Closed-loop condensation control within the enclosure
Perform in-line gravimetric sample collection for correction reference calibration
ULTRAGUARD® Fiberglass reinforced polyester NEMA 4 rated outdoor tamper-proof enclosure with internal thermal control
Optional pole or tripod mount options
Optional Cloud based data management software subscription available for remote
Size Range0.3 to 25μm
Size ChannelsFactory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm variable binning
Flow rates0.1 CFM (2.83 LPM)
Concentration Limit4,000,000 Particles/ft³ @ 5% coincidence loss
Battery Run Time10 hours
Light SourceLong life laser diode
Counting Efficiency50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
Zero Count<1 count / 5 minutes (<2 particles / ft³) (per ISO 21501-4 & JIS)
Count ModesAutomatic, manual, real-time meter, cumulative/differential, mass concentration, count or concentration
Count Alarms1 to 9,999,999 counts
CalibrationNIST traceable
Display4.3″ (10.9 cm) WQVGA (480×272) colour touchscreen
Printer (Optional)External thermal printer
Vacuum SourceInternal pump with automatic flow control
Filtered ExhaustInternal HEPA filter
Number of Channels6
Custom Size ChannelsCalibration for custom size channels available
Audible AlarmAdjustable built-in alarm
BatteryRemovable Li-ion
Battery Recharge Time4 hours within instrument (<2 hours with external battery charger)
ReportsISO 14644-1, EU GMP Annex 1, FS 209E
Recipes50 user-configurable recipes
Communication ModesEthernet and USB
Optional Communication ModesWireless 802.11 b/g, RS485 or RS232
Environmental SensorIncludes temperature and relative humidity probe 32º to 122ºF (0º to 50ºC) ±1ºF (0.5ºC), 15-90% ±2% relative humidity
AlarmAlarms on counts for all particle sizes, low battery, sensor failure, environmental sensors and flow
StandardsISO 21501-4 and JIS B9921
CalibrationRecommended minimum once per year
External SurfaceHigh impact injection moulded plastic
Dimensions (L x W x H)10” x 5” x 4.5” (25.4 cm x 12.9 cm x 11.4 cm) includes handle and does not include probes
Weight2.2 lb (1.0 kg)
AccessoriesQuick start guide, operating manual on USB flash drive, isokinetic probe, temperature relative humidity sensor, purge filter, battery, data download software, USB cable, power supply & cable
Optional AccessoriesThe printed manual, carrying case, spare battery, external battery charger, external printer and isokinetic probes
Buffer Memory45,000 sample records (rotating buffer) including particle count data, environmental data, locations and times. Scrollable on screen or printout
Sample LocationsUp to 1,000 locations 20 characters long
Sample Time1 second to 99 hours
Power110 to 240 VAC 50/60 Hz universal in-line power supply
Operating Conditions41º to 104ºF (5º to 40ºC) / 20% to 95% non-condensing
Storage Conditions32º to 122ºF (0º to 50ºC) / Up to 98% non-condensing
Warranty2 Years. Extended warranties are available.
Ambient Air Monitor diagram