Skip to content
ABCDust
Menu
Book a meeting
← All solutions

Dust and environment monitors · Monitoring instrument

Ambient air monitors

Ambient air monitors — Monitoring instrument

Designed for gas and particle pollutant measurements to better understand atmospheric chemistry and environmental public health, these internet-enabled instruments provide a near-instantaneous look at changing pollutant concentrations, with peripheral sensors for measuring environmental and meteorological parameters.

At a glance

Particle sizes
0.3–25 µm
Flow rate
0.1 CFM (2.83 L/min)
Connectivity
Optional: wireless 802.11 b/g, RS485 or RS232
Memory
45,000 records (rotating buffer)
Sampling
1 s – 99 h
Power
110–240 VAC, 50/60 Hz
Operating conditions
−20 °C to 50 °C · 20–95% RH non-condensing
Storage conditions
0–50 °C · up to 98% non-condensing

Taken from the technical text ABCDust publishes, section by section.

Model EM-10000

The EM-10000 is designed for outdoor particulate and gas monitoring. These robust monitors provide reliable, accurate measurement of airborne contamination, allowing environmental and public health concerns to be detected.

Real-time data

The 6 particle size channels recorded by the EM-10000 monitor are stored in internal non-volatile memory at user-defined sampling rates (1 second to 99 hours). The high time resolution of Model EM-10000 measurements provides a near-instantaneous look at changing airborne particulate concentrations, leading to a well-defined model of local point-source influences that may disproportionately affect air quality.

Internet-enabled

EM-10000 systems are configured to allow users to push real-time data to the cloud, where sensor outputs can be visualized by authorized stakeholders.

Fully integrated low-cost air quality sensor system

Integration of additional sensors for measuring environmental and meteorological parameters (relative humidity, temperature, barometric pressure and, optionally, carbon dioxide (CO2) and total volatile organic compounds (TVOC)) offers a more complete view of air quality.

Applications

  • Airborne pollution and environmental research
  • Perimeter or fence-line monitoring for construction, remediation or hazardous waste sites
  • Mine and quarry fence-line monitoring for dust control operations
  • City-wide or community air pollution monitoring
  • Roadside emissions monitoring
  • Medical facility property monitoring
  • Power line wildfire monitoring
  • Environmental disasters
  • Monitoring 24 hours a day, 7 days a week, 365 days a year

Features and benefits

  • Concurrent measurement of multiple user-selectable PM sizes from 0.3 µm to 10 µm, including TPM of particles up to 25 µm
  • Closed-loop humidity control for the incoming airstream (to provide more accurate particulate sizing)
  • Closed-loop condensation control within the enclosure
  • In-line gravimetric sample collection for reference calibration and correction
  • ULTRAGUARD® fibreglass-reinforced polyester, NEMA 4-rated, tamper-proof outdoor enclosure with internal thermal control
  • Optional pole or tripod mount
  • Optional cloud-based data management software subscription available for remote monitoring and access

Specifications

  • Size range: 0.3 to 25 µm
  • Size channels: factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0 and 10.0 µm; variable binning
  • Flow rate: 0.1 CFM (2.83 LPM)
  • Light source: long-life laser diode
  • Count modes: automatic, manual, real-time measurement, cumulative/differential, mass concentration, count or concentration
  • Count alarms: 1 to 9,999,999 counts
  • Calibration: NIST traceable; recommended minimum once per year
  • Display: 4.3 in (10.9 cm) WQVGA color touchscreen (480 × 272)
  • Vacuum source: internal pump with automatic flow control
  • Filtered exhaust: internal HEPA filter
  • Optional communication modes: wireless 802.11 b/g, RS485 or RS232
  • Environmental sensor: includes a temperature and relative humidity probe (−20 °C to 50 °C ±0.5 °C; 0–100% RH ±2%)
  • Alarm: alarms on counts for all particle sizes, low battery, sensor failure, environmental sensors and flow
  • Standards: ISO 21501-4 and JIS B9921
  • Buffer memory: 45,000 sample records (rotating buffer), including particle count data, environmental data, locations and times
  • Sample locations: up to 1,000 locations, 20 characters each
  • Sample time: 1 second to 99 hours
  • Power: 110 to 240 VAC, 50/60 Hz universal in-line power supply
  • Operating conditions: −20 °C to 50 °C; 20–95% RH non-condensing
  • Storage conditions: 32 to 122 °F (0 to 50 °C) / up to 98% non-condensing
  • Warranty: 1 year, limited. Extended warranties are available.